# Home Assistant automations Source of truth for the AC peak-shaving automations on the HA server (`192.168.128.3:8123`). This repo is authoritative; HA is a **deploy target** reached only through its REST config API — HA never sees these files directly. ## Utility rate context (Pepco MD, TOU-P, eff. 2026-02-01) | Season (rate) | Months | On-peak window(s), weekdays only | On-peak | Off-peak | |---|---|---|---|---| | **Summer** | Jun–Sep | **14:00–19:00** (2–7 PM) | $0.42 | $0.17 | | **Winter** | Oct–May | **06:00–09:00** and **17:00–21:00** | $0.32 | $0.13 | Weekends and **federal** holidays are always off-peak — handled by `binary_sensor.workday_sensor` (with a Mon–Fri fallback). Heating is **gas** (not on this electric peak logic), so the winter rules are **cooling-only**. ## Identity model (how a file becomes a live automation) ``` file (git) Home Assistant automations/ac_peak_setback.yaml ──deploy.py──▶ POST /api/config/automation/ id: ac_peak_setback (by id) config/ac_peak_setback alias: "AC - Peak setback to 82" │ ... ▼ registers entity automation.ac_peak_setback_to_82 ``` | Identifier | Example | Set by | Used by | Change it? | |---|---|---|---|---| | **file name** | `ac_peak_setback.yaml` | you | git only (HA never sees it) | freely | | **`id`** | `ac_peak_setback` | you (in YAML) | config API URL, traces, `automation.trigger` | **never** (primary key) | | **`alias`** | `AC - Peak setback to 82` | you (in YAML) | UI name; seeds `entity_id` at first create | rarely | | **`entity_id`** | `automation.ac_peak_setback_to_82` | HA, from `slugify(alias)` | dashboards, other automations, scripts | sticky once registered | `entity_id` derives from `alias`, not `id`. Reference automations elsewhere in HA by their `entity_id`. ## Deploying ```bash source ~/.bashrc # provides HA_API_KEY (long-lived token) python3 deploy.py --check # parse only, no writes python3 deploy.py # deploy every automations/*.yaml (in place, by id) python3 deploy.py ac_peak_ends # deploy just one by id ``` ## Parameterization (the "params map" model) Rather than duplicate summer vs winter rules, each phase is **one self-selecting automation**: - A `variables:` block computes `season` from the month (`summer` = {6,7,8,9}, else `winter`). - Time triggers carry `id: summer` / `id: winter`; the body only acts when `trigger.id == season`, so the off-season time is a harmless no-op. - Setpoints come from a `params` map (`{'summer': {'hold':82,'ret':74}, 'winter': {'hold':82,'ret':74}}`) so the two seasons can diverge later by editing one line. (Both are equal today.) The map is repeated in `ac_peak_setback` and `ac_peak_ends`; keep them in sync. ## The rules All act on `climate.t6_pro_z_wave_programmable_thermostat_with_smartstart`. ### 1. `ac_precool_before_peak` — Pre-cool before peak (summer only) - **12:00**, summer work days. Fetches today's forecast high and pre-cools: ≥90→68, ≥85→70, ≥80→71, <80→no pre-cool. - Winter has no pre-cool (marginal for an evening peak). - **Fallbacks:** workday sensor broken → Mon–Fri; forecast broken → assume 88°F → 70°F (`continue_on_error` + `fc is defined and is mapping` guard). ### 2. `ac_peak_setback` — Peak setback to 82 (both seasons) - **14:00** (summer) / **17:00** (winter), work days. - Summer: forces `cool` and sets **82**. - Winter: **cooling-only** — sets 82 *only if already in `cool` mode* (never forces mode, never touches gas heat). ### 3. `ac_peak_ends` — Peak ends, return to 74 (both seasons) - **19:00** (summer) / **21:00** (winter). Sets **74**. - Summer returns daily; winter returns only if in `cool` mode. ### 4. `ac_winter_morning_kill` — Winter morning peak kill (new in v3) - **06:00**, winter work days. If in `cool` mode, sets `hvac_mode: off` to dodge the 6–9 AM winter peak. **No auto-resume yet** (add later). Cooling-only. ## Failure-mode design | Failure | Symptom | Handled by | Default taken | |---|---|---|---| | Workday/holiday sensor unavailable | `states()` ≠ `on`/`off` | `{% if wd in ['on','off'] %}…{% else %} now().weekday()<5` | Mon–Fri | | Weather service raises | action would abort | `continue_on_error: true` | run continues | | Weather returns empty/None | `fc` undefined / not a mapping | `{% if fc is defined and fc is mapping %}…{% else %} 88` | regular pre-cool (88→70) | | Wrong-season trigger fires | `trigger.id != season` | `applies = trigger.id == season` guard | no-op | | Winter, not cooling (e.g. gas heat on) | `is_state(climate,'cool')` false | cooling-only guard | no-op (furnace safe) | Fallback and season/cooling logic verified via HA's template engine and execution traces before each deploy. ## Changelog - **2026-07-09 — v1 baseline**: imported the three live automations as-is. - **2026-07-09 — v2**: added workday + weather fallbacks to pre-cool and setback; removed throwaway debug automations (three `TEST` spoofs + `ac_flap_1758_1820`). - **2026-07-09 — v3**: TOU winter support. Pre-cool bounded to summer (Jun–Sep). `ac_peak_setback` and `ac_peak_ends` unified across seasons via a season self-select + `params` map (summer 14:00/19:00, winter 17:00/21:00), winter cooling-only. Added `ac_winter_morning_kill` (6 AM winter, cooling→off, no resume yet).